Proven Performance

TESTING DATA

ANGLELOCK® components and profiles are rigorously tested to prove every claim we make. Results below are from Instron load testing of the 40mm Heavy Duty Corner Bracket, documented in full in our Joint Technology White Paper.

Vertical Loading

Proof Load

5,100 N

Fracture Load

8,370 N

Bracket mounted to vertical profile with downward load applied. Measures structural capacity in the most common installation orientation.

Horizontal Loading

Proof Load

1,615–1,726 N

Fracture Load

2,795–3,180 N

Bracket mounted to horizontal profile with side load applied in standard and alternate directions. Tests lateral rigidity.

Moment about X-Axis

Proof Load

1,800–3,000 N·m

Fracture Load

3,000–3,690 N·m

Pure moment loading simulating door-like opening and closing forces. Tests rotational rigidity at the joint.

Moment about Y-Axis

Proof Load

480–2,260 N·m

Fracture Load

500–960 N·m

Pure moment parallel to the fixed profile, both clockwise and counterclockwise. Validates torsional joint integrity.

Torsion

Proof Load

319 N·m

Fracture Load

570–630 N·m

Pure moment about the Z-axis parallel with free profile, both clockwise and counterclockwise. Comprehensive torsion resistance analysis.